video
Globo PTA para lesiones por cierto

Globo PTA para lesiones por cierto

PTA Balloon for BTW lesions Intended use of Peripheral Balloon Catheter: Medical Peripheral Angiography Catheter used in the patient's coronary and peripheral vascular, and for a variety of diagnostic and therapeutic medical procedures.

Chatee ahora
Introducción del producto

Product Overview 

PTA Balloon for BTW lesions come in various sizes, lengths and shapes,  depending on the anatomy they're intended to treat.match with three guidewire system,{{0}}.018 inch, 0.014 inch and 0.035  inch guide wire.  With two different design, coxial and doubel lumen to met different pass-ability and push-ability. 

Uso previsto del catéter con balón periférico:
Medical Peripheral Angiography Catheter used in the patient's coronary and peripheral vascular, and for a variety of diagnostic and therapeutic medical procedures.

Product Features 


Globo PTA médico OEM para lesiones por cierto, características del catéter de dilatación con globo PTA:

  • Advanced laser bonding technology 

  • Técnica de formación de puntas con láser

  • Excelente desempeño de cruzar la estenosis

  • Soft tapered tip 

  • Compensa desalineaciones y desviaciones

  • El acanalado de globos de 3 alas

  • El alambre de núcleo cónico puede ofrecer un rendimiento de entrega excelente.

PTA-

Product Technical Specification

Compliance                                  

Balloon 

Tamaño          

Longitud del globo

Eje

longitud

Diseño de catéter

Compatibilidad con guía en pulgadas

SC  PTA Balloon

1,5 mm- 5.0 mm

20-  210mmm

100/130/150cm

coaxial

0.014

SC  PTA Balloon

2.0-9,0 mm

20-220 mm

90/130/180cm

coaxial

0.018

SC  PTA Balloon

2.0-9,0 mm

20-220 mm

90/130/180cm

lumen doble

0.018

SC  PTA Balloon

2.0-10,0 mm

20-220 mm

80/130cm

coaxial

0.035

SC  PTA Balloon

2.0-10,0 mm

20-220 mm

80/130cm

lumen doble

0.035

NC  PTA Balloon

2.0-5,0 mm

20-220 mm

100/150cm

coaxial

0.014

NC  PTA Balloon

2.0-7,0 mm

20-220 mm

90/130/180cm

coaxial

0.018

NC  PTA Balloon

2.0-7,0 mm

20-220 mm

90/130/180cm

lumen doble

0.018

NC  PTA Balloon

2.0-10,0 mm

20-220 mm

40/80/130cm

coaxial

0.035

NC  PTA Balloon

2.0-10,0 mm

20-220 mm

40/80/130cm

lumen doble

0.035

More PTA Balloon for BTW lesions ordering information please contact your sales. 

 Barty Medical Profile 

Zhejiang Barty Medical Technology Co., Ltd. was established in August 2015 in Hangzhou Economic and Technological Development Zone. Engaged in two major lines of cardiovascular, peripheral vascular intervention and implantation. There are currently more than 100 employees in Barty Medical with an average age of 28 years. Company's core members are from internationally renowned foreign medical device companies with working experience more than 15 years.

 

Preguntas más frecuentes


1. P: ¿Podemos hacer OEM para globos PTA para lesiones por cierto?

R: Sí, OEM, OBL está disponible.

2. P: ¿Cuánto tiempo es válido el producto?

R: dos años

3. ¿Qué pasa con el envío del catéter con globo periférico?

R: por mar, por DHL, EMS u otros

4. P: ¿Cuánto tiempo tomará si compro el pedido?

R: según la cantidad que necesite.

5. Q: what's the MOQ OF peripheral balloon catheter?

R: depende de la forma en que cooperamos y de la demanda de diferentes países.

Manera de contacto

Nombre: Amanda Zhu

Correo electrónico:qqzhu@batymedical.com

Mobile: plus 86 157 0559 1759 (whatsapp)


Etiqueta: globo pta para lesiones por cierto, China, proveedores, fabricantes, fábrica, personalizado, OEM

Envíeconsulta

whatsapp

skype

Correo electrónico

Consulta

bolso